| Standard Anesthesia Systems for Isoflurane (vaporizers for other anesthetic agents are available on request)  | 
|---|
| 21100 | Single-Output Anesthesia System, including Basic Single-Output Anesthesia System, scavenger (Activated Charcoal Canister), evac tubing               | 
| 21200 | Double-Output Anesthesia System, including 21050, scavenger (Activated Charcoal Canister), evac tubing and dual diverter manifold, for simultaneous connection of nose-cone/mask and induction box | 
| Delivery Systems (Masks & Induction Boxes) | 
|---|
| select from the following accessories, according to your experimental needs and to your animal model: | 
| PS-0525-A | Nose-Cone/Mask for Small Mice, with diaphragm and Inlet Adaptor | 
| PS-0305-A | Nose-Cone/Mask for Large Mice, as above, 3cm diam | 
| PS-0306-A | Nose-Cone/Mask for Small Rats, as above, 3,8cm diam | 
| PS-0307-A | Nose-Cone/Mask for Medium Rats, as above, 5cm diam. | 
| PS-0308-A | Nose-Cone/Mask for Large Rats, as above, 5.5cm diam. | 
| 7900 | Induction Box for small rodents (mice and rats), 25x13x13 (h) cm | 
| 7910 | Induction Box, large size, 40x22x21 (h) cm | 
| 21100-790 | Induction Box for small rodents (mice and rats) 25x13x13(h) cm | 
| Multiple-Output Delivery Systems | 
|---|
| PS-0529-02 | Dual Diverter Manifold with humidifier (see also 21200) | 
| PS 30-456 | Multiple-Animal Delivery System, with 2 Flowmeters | 
| PS 30-457 | Multiple-Animal Delivery System, with 3 Flowmeters | 
| PS 30-458 | Multiple-Animal Delivery System, with 4 Flowmeters | 
| PS 30-460 | Multiple-Animal Delivery System, with 5 Flowmeters | 
| PS 30-459 | Multiple-Animal Delivery System, with 6 Flowmeters | 
| Anesthetic Scavenger and Evacuation | 
|---|
| PS-0581-00 | F/air filter (activated charcoal canister) | 
| PS-0581-01 | F/air filter (activated charcoal canister), pkg. of 8 | 
| 21100-833 | Active Scavenger, to remove the anesthetic agent by applying negative pressure (can also be connected to an activated charcoal canister) | 
| Heating Pads | 
|---|
| 21100-800M | Rodent Warmer with 21100-810 Mouse Heating Pad | 
| 21100-800R | Rodent Warmer with 21100-812 Rat Heating Pad | 
| 21100-800C | Rodent Warmer with 21100-814 Cage Heating Pad | 
| 21100-304 | Rectal Thermal Probe | 
| PS-0811            | Delta-Phase Iso-therm Heating Pads (pkg of 3), 20x20x0,65cm. Maintains animal body temperature near 37°C up to several hours. Ideal for NMR | 
| Other Accessories | 
|---|
| PS-09  | Fill Device for Isoflurane | 
| PS-0949 | Fill Device for Halothane | 
| PS-0951 | Fill Device for Sevoflurane | 
| SPECIAL SYSTEMS WITH N2O | 
|---|
| 22100 | O2/N2O Anesthesia System,  complete with 2 Analog Flowmeters, TEC-3 vaporizer for Isoflurane (vaporizers for other anesthetic agents are available on request), scavenger (Activated Charcoal Canister), tubing. | 
| TO COMPLETE YOUR EQUIPMENT | 
|---|
| We also offer a complete line of Ventilators, which includes models for Mouse, Rats, Cat/Rabbit: | 
| 28025 | Mouse Ventilator, complete with 1ml or 0.5ml (model 28025-5) cylinder/piston assembly & standard accessories. Universal input 85-264 VAC, 50-60Hz | 
| 28025-150 | Connection Kit for Anesthesia System to Ventilator 28025 | 
| 7025 | Rodent Ventilator, complete with 10ml, 30ml (7025-30) or 5ml (7025-5) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz | 
| 7025-150 | Connection Kit for Anesthesia System to Ventilator 7025 | 
| 6025 | Cat/Rabbit Ventilator, complete with 50ml or 100ml (6025-100) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz | 
| 6025-150 | Connection Kit for Anesthesia System to Ventilator 6025 | 
| All ventilators are available with suitable circuit & BNC connector for synchronized START/STOP. |