Quote list0
Your product list is empty!

Animal
Mouse, Rat

Compact Gas Anesthesia System

Product Code:21100/21200

Provides and easy to use means of immobilizing an animal for surgery or procedures such as imaging. Gas Anesthesia (compared to injections) is a very quick way to induce total unconsciousness and also assists fast recovery.

High quality compact, modular and virtually unbreakable system. Reliable and precise delivery of the anesthetic gas to animals. Expandable system providing excellent value. Different masks for different animal sizes.

Model
Choose a model to get a quote...
This product warranty can be extended up to 24 Additional Months.
Discover more HERE!

Background

  • Meets the highest technical requirements of animal labs.
  • Gas anesthesia procedures generally involve an induction phase and a maintenance phase. Easily covers typical animal lab requirements with:
    • 0-4 LPM or 0-10 LPM, high precision analogue flow-meters.
    • Vaporizer
    • Induction box and mask breathing circuit.
    • Chemical scavenger or flow hood.

 High precision, cost effective expandable system

  • Anesthetize animals of virtually any size (from mouse to horse) and up to 4 animals simultaneously (depending on model).
  • High-precision analog flow-meter with 2 different flow versions (0-4 LPM and 0-10 LPM) for different sized or multiple animal delivery.
  • Reliable and precise delivery of the anesthetic gas with new, TEC3 or TEC4 vaporizers for Isoflurane, Sevoflurane and others on request.
  • Compact and portable for easy transportation and storage. 
  • Rodent masks have latex diaphragm for correct positioning and continuous flow of oxygen and anesthetic. The membrane has a positive seal to reduce the investigator’s exposure to anesthetic gases. 
  • Modular and expandable for a cost effective system that suits your needs now and in the future. Select a basic system (flowmeter and vaporizer) or start with a full system (add induction boxes, breathing circuits with masks of any size, switch valves, delivery systems for multiple animals, active and passive scavengers, etc.)
  • Blue, thick aluminum rack has a highly resistant paint to protect against stains from aggressive anesthetic liquids & solvents.
  • Two universal attachment blocks are mounted on the back, to connect the device easily to rail or mobile floor model anesthesia rigs (25x8mm up to 35x10mm).

Features

Benefits

High-precision analogue flow-meter with 2 different flow (0-4 and 0-10 LPM versions

Precise and optimal also for multiple animals

Compact and modular, make it very light and easy to carry

Portable and expandable, multichannel available

NEW, non-refurbished, TEC3 or TEC4 vaporizers

Reliable and precise delivery of the anesthetic gas

Full range of accessories

To compose a versatile full system

Different vaporizers and flowmeter

To match different anesthetizing needs and preferences

Anesthesia Systems series 21100

Dimensions

cm 26 (w) x 18 (d) x 26 (h)

Total Weight

9Kg

Shipping Weight

12Kg approx.

Packing Dimensions

40x39x30cm

Anesthesia Systems series 21200

Dimensions

cm 40 (w) x 18 (d) x 26 (h)

Total Weight

11Kg

Shipping Weight

15Kg approx.

Packing Dimensions

67x42x53cm

Warranty

Warranty Anesthesia Systems are covered by a 12-month warranty + 12 after product registration
UB-Care Additional UB-Care can be added for other 12 or 24 months

In the past decades, there has been a welcome increase in concern for the welfare of laboratory animal: increased use of Anesthetizing Systems is one of the results.

Anaesthetising laboratory animals is a significant improvement of research procedures, since it results in a lack of awareness of any potentially painful or distressing events: in fact, anaesthesia can be used to prevent pain during potentially painful procedures, such as surgery, or to provide a humane means of immobilising an animal for procedures, such as imaging.

When selecting a method of anaesthesia, it is important to consider the required depth and duration of anaesthesia and whether the method selected will cause the minimum of interference with the purpose of the research procedure. In addition the method of anaesthesia should ideally be simple to administer, without causing significant distress to the animal, free from undesirable side effects and allow a smooth and uncomplicated recovery.

Information on potentially suitable anaesthetic regimens can be obtained from a variety of sources, including the Named Veterinary Surgeon, and specialist laboratory animal anaesthesia and general veterinary anaesthesia textbooks.

(from "Anaesthesia | NC3Rs")

 

Standard Anesthesia Systems for Isoflurane

21100

Single-Output Anesthesia System, including Basic Single-Output Anesthesia System, scavenger (Activated Charcoal Canister), evac tubing              

21200

Double-Output Anesthesia System, including 21050, scavenger (Activated Charcoal Canister), evac tubing and dual diverter manifold, for simultaneous connection of nose-cone/mask and induction box

Delivery Systems (Masks & Induction Boxes)

select from the following accessories, according to your experimental needs and to your animal model:

PS-0525-A

Nose-Cone/Mask for Small Mice, with diaphragm and Inlet Adaptor

PS-0305-A

Nose-Cone/Mask for Large Mice, as above, 3cm diam

PS-0306-A

Nose-Cone/Mask for Small Rats, as above, 3,8cm diam

PS-0307-A

Nose-Cone/Mask for Medium Rats, as above, 5cm diam.

PS-0308-A

Nose-Cone/Mask for Large Rats, as above, 5.5cm diam.

7900

Induction Box for small rodents (mice and rats), 25x13x13 (h) cm

7910

Induction Box, large size, 40x22x21 (h) cm

21100-790

Induction Box for small rodents (mice and rats) 25x13x13(h) cm

Multiple-Output Delivery Systems

PS-0529-02

Dual Diverter Manifold with humidifier (see also 21200)

PS 30-456

Multiple-Animal Delivery System, with 2 Flowmeters

PS 30-457

Multiple-Animal Delivery System, with 3 Flowmeters

PS 30-458

Multiple-Animal Delivery System, with 4 Flowmeters

PS 30-460

Multiple-Animal Delivery System, with 5 Flowmeters

PS 30-459

Multiple-Animal Delivery System, with 6 Flowmeters

Anesthetic Scavenger and Evacuation

PS-0581-00

F/air filter (activated charcoal canister)

PS-0581-01

F/air filter (activated charcoal canister), pkg. of 8

21100-833

Active Scavenger, to remove the anesthetic agent by applying negative pressure (can also be connected to an activated charcoal canister)

Heating Pads

21100-800M

Rodent Warmer with 21100-810 Mouse Heating Pad

21100-800R

Rodent Warmer with 21100-812 Rat Heating Pad

21100-800C

Rodent Warmer with 21100-814 Cage Heating Pad

21100-304

Rectal Thermal Probe

PS-0811           

Delta-Phase Iso-therm Heating Pads (pkg of 3), 20x20x0,65cm. Maintains animal body temperature near 37°C up to several hours. Ideal for NMR

Other Accessories

PS-09 

Fill Device for Isoflurane

PS-0949

Fill Device for Halothane

PS-0951

Fill Device for Sevoflurane

SPECIAL SYSTEMS WITH N2O

22100

O2/N2O Anesthesia System,  complete with 2 Analog Flowmeters, TEC-3 vaporizer for Isoflurane (vaporizers for other anesthetic agents are available on request), scavenger (Activated Charcoal Canister), tubing.

TO COMPLETE YOUR EQUIPMENT

We also offer a complete line of Ventilators, which includes models for Mouse, Rats, Cat/Rabbit:

28025

Mouse Ventilator, complete with 1ml or 0.5ml (model 28025-5) cylinder/piston assembly & standard accessories. Universal input 85-264 VAC, 50-60Hz

28025-150

Connection Kit for Anesthesia System to Ventilator 28025

7025

Rodent Ventilator, complete with 10ml, 30ml (7025-30) or 5ml (7025-5) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz

7025-150

Connection Kit for Anesthesia System to Ventilator 7025

6025

Cat/Rabbit Ventilator, complete with 50ml or 100ml (6025-100) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz

6025-150

Connection Kit for Anesthesia System to Ventilator 6025

All ventilators are available with suitable circuit & BNC connector for synchronized START/STOP.

Back to: Ventilators anesthesia