7570 - Passive Avoidance - step down
The Step Down Passive Avoidance system has been designed for use with Adult Mice or juvenile rats and is based on the step-down scheme in which the animal is dropped on an elevated platform which becomes uncomfortable because of vibrations and the mouse steps down to an electrified grid.
The Passive Avoidance step-down version, for mice or immature rats, Cat. 7570
The Step Down Passive Avoidance system has been designed for use with Adult Mice or juvenile rats and is based on the step-down scheme in which the animal is dropped on an elevated platform which becomes uncomfortable because of vibrations and the mouse steps down to an electrified grid.
The Passive Avoidance step-down version, for mice or immature rats, Cat. 7570
A 7 cm platform elevated above the floor grid of a 6 x 10 x 10" box provides the arena for Step Down experiments.
The platform is connected to an actuator which causes the platform to shake. When the animal steps off of the platform to the electrified grid, the stop command is used to cut actuator power, halt platform vibration, and trigger the latency counter.
Latency time is recorded to 1/10 of a second. The vibration intensity can be changed by a thumb switch on the front panel of the instrument. An 11 cm platform is also included with this set-up, for using with larger animals.
Read More
Close
Features and Benefits
Specifications
Bibliography
| FEATURE |
BENEFIT |
| Measure memory in visually or motory impaired animals |
Avoid bias due to visual acuity differences or motory deficits |
| The platform vibrates, eliciting the animal step off |
The simple response requires very little locomotion |
| Latency counter with 1/10th of a second resolution |
Precision |
| |
|
| Start : |
via the key on the control unit |
| Stop: |
via the key on the control unit |
| Shock: |
0 to 2.9 mA, in steps of 0.1 mA |
| Latency Time: |
4-digit LED display, 0.1s steps |
| Power Requirement: |
115 or 230 V, 50/60 Hz, 18 W max |
| Operating Temperature: |
10° to 30° C |
| Sound Level |
< 70 dB |
| |
|
| Physical Dimensions: |
|
| Dimensions (7571): |
26 (w) x 30 (d) x 12 (h) cm |
| Dimensions (7573): |
28 (w) x 235 (d) x 26 (h) cm |
| Packing Dimensions: |
No. 1 Box 80 x 60 x 44 cm |
| Weight: |
Kg. 6.7 |
| Shipping Weight: |
Kg. 16.5 (approx.) |
- L. Ricceri et alia: “Postnatal Cocaine Exposure Affects Neonatal Passive Avoidance Performance and Cholinergic Development in Rats” Pharmacol. Biochem. & Behavior 45: 283-289, 1993